Daily Field Report
Date :11/14/2024
Project No :2022C205
Client Company :Pulte
Arrival Time :11/14/2024 09:00
Onsite Hours :02:30
Name of the Project :Enclave at Parkway Village
Project Location :Union City
Weather :Overcast/wet
Departure Time :11/14/2024 11:30
ASEC Technician Name :Micah Aycock
Observations/Finding
Our representative was on site to perform a foundation inspection for Lot 43. Dynamic Cone Penetrometer (DCP) testing indicated that the foundations were suitable for a soil bearing pressure of 2,000 psf and concrete placement. In-place rebar was found to meet job specifications for size, spacing and quantity.
Please notify us if you have any questions regarding this report.
Technician Signature / DateMicah Aycock, November 14, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025