- Home
- Density Test Report Report ID: 74514
- Edit Download Report
Density Test Report
Date :12/17/2024
Project No :2024C168
Client Company :CCG
Arrival Time :12/17/2024 8:00
Onsite Hours :9:00
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :12/17/2024 17:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
12/17/2024 | 376 | 17.1 | 95.1 | 26086 | 99.8 | 19.7 | 95.3 | 95 | D6938 | Pass |
Location : | retaining wall backfilling, at station 1+30, Elv/Depth :6 feet below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/17/2024 | 377 | 17.2 | 96.0 | 26086 | 99.8 | 19.7 | 96.2 | 95 | D6938 | Pass |
Location : | retaining wall back fill, at station 0+50, Elv/Depth :4.5 feet below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/17/2024 | 378 | 18.1 | 95.8 | 26086 | 99.8 | 19.7 | 96.0 | 95 | D6938 | Pass |
Location : | retaining wall back fill, at station 0+30, Elv/Depth :4.5 feet below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, December 17, 2024