Skip to content

Density Test Report

Date :09/06/2024
Project No :2024C168
Client Company :CCG
Arrival Time :09/06/2024 9:45
Onsite Hours :07:45
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :09/06/2024 17:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/06/2024 51 21.5 100.0 26081 102.9 20.0 97.2 95 D2937 Pass
Location : sewer trench, 120 feet to the NE from MHSA14., Elv/Depth :1 foot below finish grade
Comment :
09/06/2024 52 22.7 97.5 26083 102.0 22.1 95.6 95 D2937 Pass
Location : sewer trench, 101 feet to the SW from MHSA13., Elv/Depth :1 foot below finish grade
Comment :
09/06/2024 53 22.8 97.2 26083 102.0 22.1 95.3 95 D2937 Pass
Location : sewer trench, 35 feet to the SW from MHSA13., Elv/Depth :1 foot below finish grade
Comment :
09/06/2024 54 22.5 97.9 26083 102.0 22.1 96.0 95 D2937 Pass
Location : sewer trench, 123 feet to the SW from MHSA13., Elv/Depth :finished grade
Comment :
09/06/2024 55 21.8 97.6 26083 102.0 22.1 95.7 95 D2937 Pass
Location : sewer trench, 102 feet to the NE from MHSA14, Elv/Depth :finished grade
Comment :
09/06/2024 56 25.3 98.4 26081 102.9 20.0 95.6 95 D2937 Pass
Location : sewer trench, 42 feet to the SW from MHSA14., Elv/Depth :3 feet below finish grade
Comment :
Technician Signature / DateAminullah Azimi, September 6, 2024
Reviewer Name / DateRamchandra Mogulla, September 16, 2024