Skip to content

Concrete Test Report

Date :08/29/2024
Project No :2023C159
Client Company :CW Matthews
Arrival Time : 19:00
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :Clear sky
Departure Time :08/30/2024 04:15
ASEC Technician Name :Solomon Cherie

Concrete Placement Information

Location(S):
Testing: 2 Set of concrete specimens (7 Cylinders per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The cylinders will remain on site for the initial 24-48 hrs curing.
Compliance:

Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)

Deviations and/or noncompliances were noted during the field placement (refer to remarks below)

Cylinders
Pick Up:
2 Sets of concrete cylinders/ 7 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing: Cylinders were stored for the initial 24 hours
Near the poured structure
In an insulated curing box
Other
Remarks: The first one set of seven beams is for Taxiway 22 phase seven ( Airfield repair according to ASEC) whereas the second beam is for Ramp 21 project.
Technician Signature / DateSolomon Cherie, August 29, 2024