Skip to content

Density Test Report

Date :08/01/2024
Project No :2024C168
Client Company :CCG
Arrival Time :08/01/2024 13:00
Onsite Hours :05:00
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :08/01/2024 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/01/2024 1 27.6 90.3 26082 94.1 24.3 96.0 95 D6938 Pass
Location : Lot #168, Elv/Depth :8.5 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 2 28.1 89.4 26082 94.1 24.3 95.0 95 D6938 Fail
Location : Lot #167, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 3 27.1 89.5 26082 94.1 24.3 95.1 95 D6938 Pass
Location : Lot #166, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 4 28.4 90.0 26082 94.1 24.3 95.6 95 D6938 Pass
Location : Lot #165, Elv/Depth :7.5 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 5 28.3 90.9 26082 94.1 24.3 96.6 95 D6938 Pass
Location : Lot #164, Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 6 27.5 89.6 26082 94.1 24.3 95.2 95 D6938 Pass
Location : Lot #163, Elv/Depth :5 feet below finished grade
Comment : Gauge Serial No. :85759
08/01/2024 7 27.3 88.5 26082 94.1 24.3 94.0 95 D6938 Fail
Location : Sewer trench, 35 feet SW of MH A-7, Elv/Depth :12 feet below finished grade
Comment : Recompaction and restesting required. Gauge Serial No. :85759
08/01/2024 8 27.6 83.9 26085 92.0 25.3 91.2 95 D6938 Fail
Location : Sewer trench, 38 feet NW of MH A-8, Elv/Depth :10 feet below finished grade
Comment : Recompaction and restesting required. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, August 1, 2024