- Home
- Density Test Report Report ID: 68418
- Edit Download Report
Density Test Report
Date :08/01/2024
Project No :2024C168
Client Company :CCG
Arrival Time :08/01/2024 13:00
Onsite Hours :05:00
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :08/01/2024 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/01/2024 | 1 | 27.6 | 90.3 | 26082 | 94.1 | 24.3 | 96.0 | 95 | D6938 | Pass |
Location : | Lot #168, Elv/Depth :8.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 2 | 28.1 | 89.4 | 26082 | 94.1 | 24.3 | 95.0 | 95 | D6938 | Fail |
Location : | Lot #167, Elv/Depth :8 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 3 | 27.1 | 89.5 | 26082 | 94.1 | 24.3 | 95.1 | 95 | D6938 | Pass |
Location : | Lot #166, Elv/Depth :8 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 4 | 28.4 | 90.0 | 26082 | 94.1 | 24.3 | 95.6 | 95 | D6938 | Pass |
Location : | Lot #165, Elv/Depth :7.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 5 | 28.3 | 90.9 | 26082 | 94.1 | 24.3 | 96.6 | 95 | D6938 | Pass |
Location : | Lot #164, Elv/Depth :7 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 6 | 27.5 | 89.6 | 26082 | 94.1 | 24.3 | 95.2 | 95 | D6938 | Pass |
Location : | Lot #163, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/01/2024 | 7 | 27.3 | 88.5 | 26082 | 94.1 | 24.3 | 94.0 | 95 | D6938 | Fail |
Location : | Sewer trench, 35 feet SW of MH A-7, Elv/Depth :12 feet below finished grade | |||||||||
Comment : | Recompaction and restesting required. | Gauge Serial No. :85759 | ||||||||
08/01/2024 | 8 | 27.6 | 83.9 | 26085 | 92.0 | 25.3 | 91.2 | 95 | D6938 | Fail |
Location : | Sewer trench, 38 feet NW of MH A-8, Elv/Depth :10 feet below finished grade | |||||||||
Comment : | Recompaction and restesting required. | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, August 1, 2024
Reviewer Name / DateKenneth Mosman, August 05, 2024