Skip to content

Daily Field Report

Date :07/12/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :07/12/2024
Onsite Hours :
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :sunny
Departure Time :07/12/2024
ASEC Technician Name :Russell Hendrix

Observations/Finding

As requested, the site was visited by our AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services.  Visual observation techniques were employed to verify compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were observed on site this day.

Retaining Wall B Construction Report

Courses running north to south were placed on Retaining Wall B, with the footing details previously discussed in the July 11th report. Compaction was completed using a trench packer (see attached photo). Drains and geotextile fabric were placed (see attached photo). It was observed that the modular blocks were filled with No. 57 stone. The third course had less than acceptable compaction, and additional compaction was recommended. No further observations were made on this day.

 

Trench packer

First course placement

Compaction testing

Matting and drain placement

wall looking North

Wall looking South

Technician Signature / DateRussell Hendrix, July 12, 2024
Reviewer Name / DateKenneth Mosman, July 28, 2024