Skip to content

Density Test Report

Date :06/24/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :06/24/2024 9:00
Onsite Hours :08:00
Name of the Project :Sterlington
Project Location :Canton
Weather :sunny
Departure Time :06/24/2024 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/24/2024 1 15.1 96.3 P-02 105.9 18.8 90.9 95 D6938 Fail
Location : Lot #20, Elv/Depth :1 foot below finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/24/2024 2 15.2 96.4 P-02 105.9 18.8 91.0 95 D6938 Fail
Location : Lot #18, Elv/Depth :finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/24/2024 3 15.3 96.0 P-02 105.9 18.8 90.7 95 D6938 Fail
Location : Lot #19, Elv/Depth :1 foot below finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/24/2024 4 15.6 96.9 P-02 105.9 18.8 91.5 95 D6938 Fail
Location : Lot #24, Elv/Depth :finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/24/2024 5 16.3 94.8 P-02 105.9 18.8 89.5 95 D6938 Fail
Location : Lot #25, Elv/Depth :finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
Technician Signature / DateAminullah Azimi, June 24, 2024
Reviewer Name / DateKenneth Mosman, July 24, 2024