- Home
- Density Test Report Report ID: 66814
- Edit Download Report
Density Test Report
Date :06/30/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :06/30/2024 12:30
Onsite Hours :06:00
Name of the Project :Sterlington
Project Location :Canton
Weather :sunny
Departure Time :06/30/2024 18:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
06/30/2024 | 1 | 17.7 | 99.4 | P-02 | 105.9 | 18.8 | 93.9 | 95 | D6938 | Fail |
Location : | Lot #8, Elv/Depth :7 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/30/2024 | 2 | 16 | 95.4 | P-02 | 105.9 | 18.8 | 90.1 | 95 | D6938 | Fail |
Location : | Lot #8, basement, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/30/2024 | 3 | 18.9 | 100.5 | P-02 | 105.9 | 18.8 | 94.9 | 95 | D6938 | Fail |
Location : | Lot #8, Elv/Depth :6 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/30/2024 | 4 | 15.7 | 99.0 | P-02 | 105.9 | 18.8 | 93.5 | 95 | D6938 | Fail |
Location : | Lot #8, basement, Elv/Depth :4.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/30/2024 | 5 | 18.9 | 100.0 | P-02 | 105.9 | 18.8 | 94.4 | 95 | D6938 | Fail |
Location : | Lot #8, Elv/Depth :5.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateAminullah Azimi, June 30, 2024
Reviewer Name / DateKenneth Mosman, July 25, 2024