Density Test Report
Date :04/26/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :04/26/2024
Onsite Hours :
Name of the Project :Sterlington
Project Location :Canton
Weather :overcast
Departure Time :04/26/2024
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/26/2024 | 1 | 27.5 | 79.5 | P-01 | 94.8 | 25.0 | 83.9 | 98 | D6938 | Fail |
Location : | 10 feet south of A6, Elv/Depth :-1 foot from finished | |||||||||
Comment : | Recommended scarify and recompaction | Gauge Serial No. :30942 | ||||||||
04/26/2024 | 1 | 18.2 | 105.0 | P-01 | 94.8 | 25.0 | 93.7 | 95 | D6938 | Fail |
Location : | Lot #10, Elv/Depth :- 3 feet from finished | |||||||||
Comment : | recommended additional compaction | Gauge Serial No. :30942 | ||||||||
04/26/2024 | Re-test #1 | 19.5 | 94.3 | P-01 | 94.8 | 25.0 | 99.5 | 95 | D6938 | Pass |
Location : | Lot #10, Elv/Depth :-3 feet from finished | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
04/26/2024 | Re-test #2 | 18.8 | 95.5 | P-01 | 94.8 | 25.0 | 100.7 | 95 | D6938 | Pass |
Location : | Lot #11, Elv/Depth :- 3 feet from finished | |||||||||
Comment : | Gauge Serial No. :30942 |
Technician Signature / DateRussell Hendrix, April 26, 2024