- Home
- Density Test Report Report ID: 66237
- Edit Download Report
Density Test Report
Date :04/26/2024
Project No :2023C180
Client Company :Artisan Communities
Arrival Time :04/26/2024 10:30
Onsite Hours :05:30
Name of the Project :Lakeside Sub. - Lovers Lane, Calhoun
Project Location :Calhoun
Weather :sunny
Departure Time :04/26/2024 16:00
ASEC Technician Name :
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/26/2024 | 1 | 25.8 | 87.9 | P-01 | 97.0 | 19.1 | 90.6 | 90 | D6938 | Pass |
Location : | Sewer line, 38 feet north from SSMH 6.1., Elv/Depth :2 feet below finished grade | |||||||||
Comment : | Moisture content is more than 3 percent over optimum moisture content | Gauge Serial No. :3430 | ||||||||
04/26/2024 | 2 | 24.9 | 89.1 | P-01 | 97.0 | 19.1 | 91.9 | 90 | D6938 | Pass |
Location : | Sewer line, 43 feet west from SSMH 6.2., Elv/Depth :1.5 feet below finished grade | |||||||||
Comment : | Moisture content is more than 3 percent over optimum moisture content | Gauge Serial No. :3430 | ||||||||
04/26/2024 | 3 | 21.5 | 86.1 | P-02 | 91.6 | 25.6 | 94.0 | 90 | D6938 | Pass |
Location : | water storm line, 53 feet west from MH AE2., Elv/Depth :1 foot below finished grade | |||||||||
Comment : | Moisture content is more than 3 percent over optimum moisture content | Gauge Serial No. :3430 | ||||||||
04/26/2024 | 4 | 27.3 | 87.6 | P-01 | 97.0 | 19.1 | 90.3 | 90 | D6938 | Pass |
Location : | sewer line, 41 feet NE from SSMH 6.2, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Moisture content is more than 3 percent over optimum moisture content | Gauge Serial No. :3430 | ||||||||
04/26/2024 | 5 | 29.1 | 84.0 | P-02 | 91.6 | 25.6 | 91.7 | 90 | D6938 | Pass |
Location : | Sewer line, 45 feet SW from SSMH 6.3, Elv/Depth :3 feet below finished grade | |||||||||
Comment : | Moisture content is more than 3 percent over optimum moisture content | Gauge Serial No. :3430 |
Technician Signature / DateAminullah Azimi, April 26, 2024
Reviewer Name / DateKenneth Mosman, May 23, 2024