- Home
- Density Test Report Report ID: 66060
- Edit Download Report
Density Test Report
Date :04/19/2024
Project No :2022C106
Client Company :CWM
Arrival Time :04/19/2024 10:30
Onsite Hours :07:30
Name of the Project :Taxiway 2022 Pavement Replacement
Project Location :HJAIA
Weather :sunny
Departure Time :04/19/2024 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/19/2024 | 1 | 4 | 134.2 | GAB 1 | 135.6 | 6.8 | 99.0 | 95 | D6938 | Pass |
Location : | 76 feet north of purposed NLVR, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/19/2024 | 2 | 4.3 | 130.5 | GAB 1 | 135.6 | 6.8 | 96.2 | 95 | D6938 | Pass |
Location : | 31 feet north of NLVR, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/19/2024 | 3 | 4.6 | 131.5 | GAB 1 | 135.6 | 6.8 | 97.0 | 95 | D6938 | Pass |
Location : | 15 feet south of NLVR , Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 19, 2024
Reviewer Name / DateKenneth Mosman, May 23, 2024