- Home
- Density Test Report Report ID: 65929
- Edit Download Report
Density Test Report
Date :04/07/2024
Project No :2022C106
Client Company :CWM
Arrival Time :04/07/2024 8:00
Onsite Hours :06:00
Name of the Project :Taxiway 2022 Pavement Replacement
Project Location :HJAIA
Weather :
Departure Time :04/07/2024 14:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/07/2024 | 1 | 5 | 131.4 | GAB 1 | 135.6 | 6.8 | 96.9 | 95 | D6938 | Pass |
Location : | Storm water pipe, 52 feet from A2, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/07/2024 | 2 | 5.1 | 130.1 | GAB 1 | 135.6 | 6.8 | 95.9 | 95 | D6938 | Pass |
Location : | storm water line, 121 feet west of MHA-2, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/07/2024 | 3 | 5.6 | 115.5 | Infinity | D6938 | Pass | ||||
Location : | Existing storm pipe, 60 feet North of NLVR , Elv/Depth :9 inches below finished grade | |||||||||
Comment : | Note: We need add proctor of M10 for result, | Gauge Serial No. :85759 | ||||||||
04/07/2024 | 4 | 7.5 | 132.1 | Infinity | D6938 | Pass | ||||
Location : | Existing storm water pipe, 15 feet west of NLVR , Elv/Depth :8 inches below finish grade | |||||||||
Comment : | Note: need to add proctor for M10 for result, | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 7, 2024
Reviewer Name / DateKenneth Mosman, April 26, 2024