- Home
- Density Test Report Report ID: 65865
- Edit Download Report
Density Test Report
Date :04/06/2024
Project No :2022C106
Client Company :CWM
Arrival Time :04/06/2024 6:30
Onsite Hours :9:00
Name of the Project :Taxiway 2022 Pavement Replacement
Project Location :HJAIA
Weather :sunny
Departure Time :04/06/2024 15:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/06/2024 | 1 | 7.2 | 134.5 | GAB 1 | 135.6 | 6.8 | 99.2 | 95 | D6938 | Pass |
Location : | N:9153.472 E: 13993.73 , Elv/Depth :finished grade or Elev: 974.571 | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/06/2024 | 2 | 6.5 | 134.1 | GAB 1 | 135.6 | 6.8 | 98.9 | 95 | D6938 | Pass |
Location : | N: 9152.86 E: 13948.36, Elv/Depth :finished grade or Elev: 975.02 | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/06/2024 | 3 | 5.3 | 134.2 | GAB 1 | 135.6 | 6.8 | 99.0 | 95 | D6938 | Pass |
Location : | N: 9230.05 E: 13952.04, Elv/Depth :Finished grade or 973.906 | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/06/2024 | 4 | 5.9 | 133.3 | GAB 1 | 135.6 | 6.8 | 98.3 | 95 | D6938 | Pass |
Location : | N: 9231.06 E: 14005.89, Elv/Depth :finished grade or 973.34 | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 6, 2024
Reviewer Name / DateKenneth Mosman, April 25, 2024