- Home
- Density Test Report Report ID: 65425
- Edit Download Report
Density Test Report
Date :03/21/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :03/21/2024 7:30
Onsite Hours :06:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :sunny
Departure Time :03/21/2024 13:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
03/21/2024 | 1 | 9.4 | 119.2 | 9 | 120.8 | 11.3 | 98.7 | 95 | D6938 | Pass |
Location : | Bend 11 or STA 7005+30.86, Elv/Depth :3.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/21/2024 | 2 | 10.5 | 130.5 | 9 | 120.8 | 11.3 | 97.8 | 95 | D6938 | Pass |
Location : | Bend 11 or STA 7005+30.86, Elv/Depth :3 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/21/2024 | 3 | 11.2 | 119.9 | 9 | 120.8 | 11.3 | 99.3 | 95 | D6938 | Pass |
Location : | Bend 11 or STA 7005+30.86, Elv/Depth :2.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/21/2024 | 4 | 8 | 120.5 | 9 | 120.8 | 11.3 | 99.8 | 95 | D6938 | Pass |
Location : | Bend 11 or STA 7005+30.86, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, March 21, 2024
Reviewer Name / DateKenneth Mosman, March 28, 2024