- Home
- Density Test Report Report ID: 64456
- This project is inactive from admin.Download Report
Density Test Report
Date :02/24/2024
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :02/24/2024 7:30
Onsite Hours :04:30
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :sunny
Departure Time :02/24/2024 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
02/24/2024 | 1 | 22.2 | 100.3 | 24208 | 110.4 | 16.3 | 90.9 | 90 | D6938 | Pass |
Location : | Finished grade of outlet of pond #1, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/24/2024 | 2 | 18.7 | 100.2 | SC | 94.6 | 21.9 | 105.9 | 100 | D6938 | Pass |
Location : | Roadway between Lot #9 and Lot #28, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, February 24, 2024
Reviewer Name / DateRamchandra Mogulla, June 18, 2024