- Density Test Report Report ID: 63467
- This project is inactive from admin.Download Report
Density Test Report
Date :12/20/2023
Project No :2023C141
Client Company :Toll Bros
Arrival Time :12/20/2023 12:00
Onsite Hours :04:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :12/20/2023 16:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
12/20/2023 | 1 | 16.9 | 104.4 | 24468 | 111.3 | 17.5 | 93.8 | 90 | D6938 | Pass |
Location : | Lot #40, Elv/Depth :6 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/20/2023 | 2 | 17.4 | 107.3 | 24468 | 111.3 | 17.5 | 96.4 | 90 | D6938 | Pass |
Location : | Basement of Lot #39, Elv/Depth :5 feet below from basement finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, December 20, 2023
Reviewer Name / DateKenneth Mosman, March 09, 2024