Density Test Report

Date :12/19/2023
Project No :2023C141
Client Company :Toll Bros
Arrival Time :12/19/2023 12:00
Onsite Hours :04:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :12/19/2023 16:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/19/2023 1 14.9 102.7 24468 111.3 17.5 92.3 90 D6938 Pass
Location : Lot #32, Elv/Depth :8 feet below finished grade
Comment : Gauge Serial No. :85759
12/19/2023 2 17.5 101.1 24468 111.3 17.5 90.8 90 D6938 Pass
Location : Roadway in the front of Lot #32., Elv/Depth :6.5 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, December 19, 2023
Reviewer Name / DateKenneth Mosman, March 09, 2024