- Concrete Test Report Report ID: 61889
- This project is inactive from admin.Download Report
Concrete Test Report
Date :09/20/2023
Project No :2023C136
Client Company :Excellere
Arrival Time :09/20/2023 9:00
Onsite Hours :06:30
Name of the Project :Big Creek Boardwalks
Project Location :Alpharetta
Weather :sunny
Departure Time :09/20/2023 15:30
ASEC Technician Name :Aminullah Azimi
Concrete Placement Information
Location(S):
Testing:
A Set of concrete specimens (6 Cylinders per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The cylinders will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Cylinders
Pick Up: A Sets of concrete cylinders/ 6 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: A Sets of concrete cylinders/ 6 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Cylinders were stored for the initial 24 hours
Near the poured structure
In an insulated curing box
Other
Remarks:
Note: batch-to-placement time and slump did not meet job specifications.
Field Test Data
Set Number :A
Date Sampled :09/20/2023
Sampled By :Aminullah Azimi
Contractor :Excellere Cnstraction.LLC
Truck Number :2279
Time Batched :9:33
Location of Placement : from Pile Number 29 to Pile number 31,
Number of samples cast :6
Ambient Temperature (°f) :70
Slump (in.) :6.5
Water added (gal.) :0
Laboratory Number :A
Time Sampled :10:30
Weather Condition :sunny
Concrete Supplier :Thomas
Mix ID :408003FA
Quantity of Load (cu. yd.) :9
Sample Cast :A
Specified Strength :4000
Concrete Temperature(°f) :78
Air Content (%) :70
Strength Test Results
Specimen Number | Age (days) | Date Tested | Dia(in.) | Area (sq in.) | Maximum Loads (lbs) | Strength (lbs) | % Design Strength | Type of Fracture |
---|---|---|---|---|---|---|---|---|
A | 0 | 09/20/2023 |
UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.
(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed
Technician Signature / DateAminullah Azimi, September 20, 2023
Reviewer Name / DateKenneth Mosman, October 01, 2023