Density Test Report
Date :09/13/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :09/13/2023 06:00
Onsite Hours :10:30
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :SUNNY
Departure Time :09/13/2023 16:30
ASEC Technician Name :Avinash Bandham
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/13/2023 | 4 | 16.1 | 109.6 | ASEC-2 | 110.9 | 15.3 | Check | |||
Location : | Section 2 basement area G7 , Elv/Depth :276 | |||||||||
Comment : | ||||||||||
09/13/2023 | 1 | 17.6 | 106.5 | ASEC-2 | 110.9 | 15.3 | 96.0 | 95 | D6938 | Pass |
Location : | Section 1 basement area B7, Elv/Depth :278 | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
09/13/2023 | 2 | 16.2 | 105.5 | ASEC-2 | 110.9 | 15.3 | 95.1 | 95 | D6938 | Pass |
Location : | Section 2 basement area G7, Elv/Depth :277 | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
09/13/2023 | 3 | 15.7 | 105.3 | ASEC-2 | 110.9 | 15.3 | 95.0 | 95 | D6938 | Fail |
Location : | Section 2 basement area G7 , Elv/Depth :276.5 | |||||||||
Comment : | Gauge Serial No. :30942 |