- Density Test Report Report ID: 57963
- Edit Download Report
Density Test Report
Date :03/22/2023
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :03/22/2023 11:30
Onsite Hours :08:00
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :cloudy
Departure Time :03/22/2023 19:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
03/22/2023 | 1 | 26.5 | 89.6 | 2 | 95.0 | 23.5 | 94.3 | 90 | D6938 | Pass |
Location : | 30 feet to the West, Elv/Depth :7 feet below finished grade. | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 2 | 25.1 | 95.4 | 2 | 95.0 | 23.5 | 100.4 | 90 | D6938 | Pass |
Location : | 40 feet to the West of MH B2, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 3 | 26.7 | 90.4 | 2 | 95.0 | 23.5 | 95.2 | 90 | D6938 | Pass |
Location : | 45 feet to the East of MH B1, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 4 | 26.8 | 89.0 | 2 | 95.0 | 23.5 | 93.7 | 90 | D6938 | Pass |
Location : | 15 feet to the West of MH B2, Elv/Depth :4 below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 5 | 22.1 | 91.8 | 2 | 95.0 | 23.5 | 96.6 | 90 | D6938 | Pass |
Location : | 25 feet to the West of MH B2, Elv/Depth :3 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 6 | 24.8 | 97.2 | 2 | 95.0 | 23.5 | 102.3 | 90 | D6938 | Pass |
Location : | 30 feet to the East of MH B1, Elv/Depth :3.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 7 | 26.4 | 85.8 | 2 | 95.0 | 23.5 | 90.3 | 90 | D6938 | Pass |
Location : | 20 feet West of MH B2, Elv/Depth :2 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 8 | 26.8 | 91.2 | 2 | 95.0 | 23.5 | 96.0 | 90 | D6938 | Pass |
Location : | 105 feet to the East of MH B1, Elv/Depth :2.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/22/2023 | 9 | 26.4 | 90.1 | 2 | 95.0 | 23.5 | 94.8 | 90 | D6938 | Pass |
Location : | 110 feet to West MH B2, Elv/Depth :2 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, March 22, 2023
Reviewer Name / DateKenneth Mosman, April 07, 2023