Skip to content

Density Test Report

Date :02/14/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :02/14/2023 10:00
Onsite Hours :08:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :cloudy
Departure Time :02/14/2023 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/14/2023 1 17 106.7 P-01 100.4 18.6 90.8 90 D6938 Pass
Location : Lot #427, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
02/14/2023 2 18.3 90.5 P-01 100.4 18.6 90.1 90 D6938 Pass
Location : Lot #426, Elv/Depth :-1.5' from finished grade
Comment : Gauge Serial No. :85759
02/14/2023 3 17.5 95.1 P-01 100.4 18.6 94.7 90 D6938 Pass
Location : at roadway, Elv/Depth :-5' from finished grade
Comment : Gauge Serial No. :85759
02/14/2023 4 16 93.0 P-01 100.4 18.6 92.6 90 D6938 Pass
Location : Lot #424, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
02/14/2023 5 15.7 95.5 P-01 100.4 18.6 95.1 90 D6938 Pass
Location : Lot #423, Elv/Depth :-1.5' from finished grade
Comment : Gauge Serial No. :85759
02/14/2023 6 15.7 96.4 P-01 100.4 18.6 96.0 90 D6938 Pass
Location : Lot #428, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
02/14/2023 7 16.7 94.3 P-01 100.4 18.6 93.9 90 D6938 Pass
Location : Lot #422, Elv/Depth :-2.5' from finished grade
Comment : Gauge Serial No. :85759
02/14/2023 8 19.8 98.6 P-01 100.4 18.6 98.2 90 D6938 Pass
Location : at roadway, Elv/Depth :-1' from finished grade
Comment : Gauge Serial No. :85759
02/14/2023 9 16.2 97.2 P-01 100.4 18.6 96.8 90 D6938 Pass
Location : Lot #423, Elv/Depth :-6 inches from finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 14, 2023
Reviewer Name / DateKenneth Mosman, February 19, 2023