Skip to content

Density Test Report

Date :10/05/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :10/05/2022 10:00
Onsite Hours :05:00
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :Sunny
Departure Time :10/05/2022 15:00
ASEC Technician Name :Vidal Dias

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/05/2022 1 13.8 110.8 P-1 97.3 23.7 113.9 95 D6938 Pass
Location : 5 feet from the anti-seepage collar towards manhole, Elv/Depth :
Comment : Gauge Serial No. :
10/05/2022 2 14.3 109.1 P-1 97.3 23.7 112.1 95 D6938 Pass
Location : 5 feet from manhole, Elv/Depth :
Comment : Gauge Serial No. :
10/06/2022 3 23.7 88.3 P-1 97.3 23.7 90.8 95 D6938 Fail
Location : 3 feet from anti-seepage collar , Elv/Depth :
Comment : Gauge Serial No. :
10/08/2022 4 26.7 96.3 P-1 97.3 23.7 99.0 95 D6938 Pass
Location : 3 feet from manhole, Elv/Depth :
Comment : Gauge Serial No. :
10/09/2022 5 18.8 109.1 P-1 97.3 23.7 112.1 95 D6938 Pass
Location : 6 feet from manhole, Elv/Depth :
Comment : Gauge Serial No. :
10/09/2022 6 20 103.5 P-1 97.3 23.7 106.4 95 D6938 Pass
Location : 6 feet from anti seepage collar towards outlet , Elv/Depth :
Comment : Gauge Serial No. :
Technician Signature / DateVidal Dias, October 5, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022