- Home
- Density Test Report Report ID: 52973
- This project is inactive from admin.Download Report
Density Test Report
Date :01/25/2022
Project No :2021C082
Client Company :CCG Constructors LLC (Century)
Arrival Time :01/14/2022 13:00
Onsite Hours :03:00
Name of the Project :Estates at Old Friendship
Project Location :Buford, GA
Weather :52, sunny
Departure Time :01/14/2022 16:00
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
01/14/2022 | 1 | 26.8 | 86.1 | P-2 | 102.2 | 20.3 | 84.2 | 95 | D6938 | Fail |
Location : | A7-A71, storm drain on main entrance road, Elv/Depth :+1 | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
01/14/2022 | 2 | 23.1 | 73.3 | P-2 | 102.2 | 20.3 | 71.7 | 95 | D6938 | Fail |
Location : | A7-A71, Elv/Depth :+1 | |||||||||
Comment : | Discussed with foreman excessive soil moisture levels and not being able to achieve needed compaction. | Gauge Serial No. :38069 | ||||||||
01/14/2022 | 3 | 14.9 | 91.9 | P-2 | 102.2 | 20.3 | 89.9 | 95 | D6938 | Fail |
Location : | A7-A71, Elv/Depth :+2 | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
01/14/2022 | 4 | 21.9 | 82.7 | P-2 | 102.2 | 20.3 | 80.9 | 95 | D6938 | Fail |
Location : | A7-A71, Elv/Depth :+3 | |||||||||
Comment : | At end of work day this trench was filled to allow construction traffic to pass. It is to be re-excavated every morning to resume work. | Gauge Serial No. :38069 |
Technician Signature / DateRussell Hendrix, January 25, 2022
Reviewer Name / DateKenneth Mosman, February 16, 2023