Skip to content

Density Test Report

Date :11/10/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :11/10/2021 12:30
Onsite Hours :05:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :11/10/2021 17:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/10/2021 1 17.8 99.9 P-3 103.0 18.1 97.0 95 D6938 Pass
Location : Road between lot 353 and 307, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
11/10/2021 2 12.2 103.6 P-3 103.0 18.1 100.6 95 D6938 Pass
Location : Road between lot 355 and 309, Elv/Depth :2’ below final grade
Comment : Gauge Serial No. :38069
11/10/2021 3 13.1 102.2 P-3 103.0 18.1 99.2 95 D6938 Pass
Location : Road between lot 354 and 308, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
11/10/2021 4 12.7 99.7 P-3 103.0 18.1 96.8 95 D6938 Pass
Location : road between lot 355 and 309, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, November 10, 2021
Reviewer Name / DateKenneth Mosman, December 06, 2021