- Home
- Density Test Report Report ID: 34498
- This project is inactive from admin.Download Report
Density Test Report
Date :11/02/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :11/02/2021 14:30
Onsite Hours :02:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :11/02/2021 17:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/02/2021 | 1 | 18.8 | 105.7 | P-2 | 111.3 | 14.6 | 95.0 | 95 | D6938 | Fail |
Location : | Road in front of lot 288, Elv/Depth :2’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
11/02/2021 | 2 | 15.6 | 98.7 | P-3 | 103.0 | 18.1 | 95.8 | 95 | D6938 | Pass |
Location : | Road in front of lot 287, Elv/Depth :2’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateChristopher Burrow II, November 2, 2021
Reviewer Name / DateKenneth Mosman, December 06, 2021