- Home
- Density Test Report Report ID: 34496
- This project is inactive from admin.Download Report
Density Test Report
Date :11/02/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :11/02/2021 12:00
Onsite Hours :02:30
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :11/02/2021 14:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/02/2021 | 1 | 19.8 | 96.4 | P-01 | 93.9 | 22.6 | 102.7 | 95 | D6938 | Pass |
Location : | Manhole A4, Elv/Depth :6’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
11/02/2021 | 2 | 22.3 | 84.9 | P-04 | 88.5 | 28.4 | 95.9 | 95 | D6938 | Pass |
Location : | Manhole A5, Elv/Depth :6’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateChristopher Burrow II, November 2, 2021
Reviewer Name / DateKenneth Mosman, December 10, 2021