- Home
- Density Test Report Report ID: 33969
- This project is inactive from admin.Download Report
Density Test Report
Date :09/13/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/13/2021 09:00
Onsite Hours :07:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/13/2021 16:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/13/2021 | 1 | 18.2 | 99.7 | P-3 | 103.0 | 18.1 | 96.8 | 95 | D2937 | Pass |
Location : | Center of lot 316, Elv/Depth :3’ below final grade | |||||||||
Comment : | ||||||||||
09/13/2021 | 2 | 18.7 | 99.0 | P-3 | 103.0 | 18.1 | 96.1 | 95 | D2937 | Pass |
Location : | Roadway between lot 293 & 296, Elv/Depth :5’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, September 13, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021