Skip to content

Density Test Report

Date :09/13/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/13/2021 09:00
Onsite Hours :07:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/13/2021 16:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/13/2021 1 18.2 99.7 P-3 103.0 18.1 96.8 95 D2937 Pass
Location : Center of lot 316, Elv/Depth :3’ below final grade
Comment :
09/13/2021 2 18.7 99.0 P-3 103.0 18.1 96.1 95 D2937 Pass
Location : Roadway between lot 293 & 296, Elv/Depth :5’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, September 13, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021