- Home
- Density Test Report Report ID: 33755
- This project is inactive from admin.Download Report
Density Test Report
Date :09/03/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :09/03/2021 07:15
Onsite Hours :03:30
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :sunny
Departure Time :09/03/2021 10:45
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/03/2021 | 1 | 19.8 | 117.8 | P-01 | 102.0 | 16.6 | 96.4 | 95 | D6938 | Pass |
Location : | back of lot 117, Elv/Depth :895 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 2 | 20.9 | 103.3 | P-02 | 105.6 | 16.6 | 97.8 | 95 | D6938 | Pass |
Location : | backk of lot 119, Elv/Depth :893 | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateRussell Hendrix, September 3, 2021
Reviewer Name / DateRamchandra Mogulla, November 18, 2021