- Home
- Density Test Report Report ID: 33753
- This project is inactive from admin.Download Report
Density Test Report
Date :09/03/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :09/03/2021 07:15
Onsite Hours :03:30
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :sunny
Departure Time :09/03/2021 10:45
ASEC Technician Name :
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/03/2021 | 1 | 17.7 | 104.0 | P-02 | 105.6 | 16.6 | 98.5 | 95 | D6938 | Pass |
Location : | back of lot 105, Elv/Depth :900 | |||||||||
Comment : | Gauge Serial No. :295888 | |||||||||
09/03/2021 | 2 | 19.3 | 108.0 | P-02 | 105.6 | 16.6 | 102.3 | 95 | D6938 | Pass |
Location : | back of lot 106, Elv/Depth :900 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 3 | 18.1 | 102.5 | P-02 | 105.6 | 16.6 | 97.1 | 95 | D6938 | Pass |
Location : | back of lot 107, Elv/Depth :898 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 4 | 17.1 | 98.3 | P-01 | 102.0 | 16.6 | 96.4 | 95 | D6938 | Pass |
Location : | back of lot 108, Elv/Depth :898 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 5 | 13.6 | 104.0 | P-01 | 102.0 | 16.6 | 102.0 | 95 | D6938 | Pass |
Location : | back of lot 109, Elv/Depth :896 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 6 | 15.4 | 105.4 | P-01 | 102.0 | 16.6 | 103.3 | 95 | D6938 | Pass |
Location : | back of lot 110, Elv/Depth :896 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 7 | 25.9 | 105.9 | P-01 | 102.0 | 16.6 | 103.8 | 95 | D6938 | Pass |
Location : | back of lot 111, Elv/Depth :896 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 8 | 19.6 | 104.9 | P-01 | 102.0 | 16.6 | 102.8 | 95 | D6938 | Pass |
Location : | back of lot 117, Elv/Depth :894 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 9 | 16.9 | 103.8 | P-01 | 102.0 | 16.6 | 101.8 | 95 | D6938 | Pass |
Location : | back of lot 118, Elv/Depth :894 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 10 | 14.6 | 104.2 | P-01 | 102.0 | 16.6 | 102.2 | 95 | D6938 | Pass |
Location : | back of lot 119, Elv/Depth :892 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 11 | 18.8 | 97.2 | P-01 | 102.0 | 16.6 | 95.3 | 95 | D6938 | Pass |
Location : | back of lot 120, Elv/Depth :890 | |||||||||
Comment : | Gauge Serial No. :295888 | |||||||||
09/03/2021 | 12 | 19.1 | 97.5 | P-01 | 102.0 | 16.6 | 95.6 | 95 | D6938 | Pass |
Location : | back of lot 121, Elv/Depth :890 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/03/2021 | 13 | 21.9 | 107.6 | P-01 | 102.0 | 16.6 | 105.5 | 95 | D6938 | Pass |
Location : | back of lot 122, Elv/Depth :888 | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateRussell Hendrix, September 3, 2021
Reviewer Name / DateRamchandra Mogulla, November 18, 2021