- Home
- Density Test Report Report ID: 33687
- This project is inactive from admin.Download Report
Density Test Report
Date :09/07/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :08/27/2021 09:15
Onsite Hours :04:45
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :sunny
Departure Time :08/27/2021 14:00
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/27/2021 | 1 | 19.8 | 92.7 | P-01 | 102.0 | 16.6 | 90.9 | 90 | D6938 | Pass |
Location : | back of subdivision near detention pond, Elv/Depth :790 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/27/2021 | 2 | 18.5 | 92.3 | P-01 | 102.0 | 16.6 | 90.5 | 90 | D6938 | Pass |
Location : | back of subdivision near detention pond, Elv/Depth :790 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/27/2021 | 3 | 21.2 | 92.7 | P-01 | 102.0 | 16.6 | 90.9 | 90 | D6938 | Pass |
Location : | back of subdivision near detention pond, Elv/Depth :790 | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateRussell Hendrix, September 7, 2021
Reviewer Name / DateRamchandra Mogulla, November 07, 2021