Density Test Report
Date :08/04/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :08/04/2021 16:00
Onsite Hours :02:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :08/04/2021 18:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/04/2021 | 1 | 17.6 | 100.9 | P-3 | 103.0 | 18.1 | 98.0 | 95 | D2937 | Pass |
Location : | Center of line between lot 294 & 295, Elv/Depth :10’ Below Final Grade | |||||||||
Comment : | ||||||||||
08/04/2021 | 2 | 17.8 | 99.1 | P-3 | 103.0 | 18.1 | 96.2 | 95 | D2937 | Pass |
Location : | Center of line between lot 295 and retention pond, Elv/Depth :9’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, August 4, 2021
Reviewer Name / DateRamchandra Mogulla, September 07, 2021