- Home
- Density Test Report Report ID: 33522
- This project is inactive from admin.Download Report
Density Test Report
Date :08/05/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :08/05/2021 07:00
Onsite Hours :02:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :08/05/2021 09:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/05/2021 | 1 | 16.6 | 97.4 | P-01 | 93.9 | 22.6 | 103.7 | 95 | D2937 | Pass |
Location : | Center of lot 402 20’ from woods, Elv/Depth :4’ below final grade | |||||||||
Comment : | ||||||||||
08/05/2021 | 2 | 17.2 | 98.1 | P-01 | 93.9 | 22.6 | 104.5 | 95 | D2937 | Pass |
Location : | Center of lot 403 30’ from woods, Elv/Depth :3’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, August 5, 2021
Reviewer Name / DateRamchandra Mogulla, March 29, 2023