- Home
- Density Test Report Report ID: 1361
- This project is inactive from admin.Download Report
Density Test Report
Date :11/11/2020
Project No :
Client Company :DR Horton
Arrival Time :11/11/2020 10:00
Onsite Hours :04:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :11/11/2020 14:00
ASEC Technician Name :Ramchandra Mogulla
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/11/2020 | 10 | 16.8 | 93.4 | P-2 | 102.3 | 18.0 | 91.3 | 90 | D2937 | Pass |
Location : | Lot # 9 and vicinity, Elv/Depth :- 7 feet | |||||||||
Comment : | ||||||||||
11/11/2020 | 11 | 15.8 | 92.8 | P-2 | 102.3 | 18.0 | 90.7 | 90 | D2937 | Pass |
Location : | Lot # 9 and vicinity, Elv/Depth :-6 feet | |||||||||
Comment : |
Technician Signature / DateRamchandra Mogulla, November 11, 2020
Reviewer Name / DateKenneth Mosman, December 15, 2021