Skip to content

Density Test Report

Date :11/05/2020
Project No :
Client Company :DR Horton
Arrival Time :11/05/2020 10:00
Onsite Hours :06:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :11/05/2020 16:00
ASEC Technician Name :Ramchandra Mogulla

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/05/2020 8 19.8 92.5 P-2 102.3 18.0 90.4 90 D2937 Pass
Location : Lot # 9, Elv/Depth :-8 feet
Comment :
11/05/2020 9 15.4 98.7 P-2 102.3 18.0 96.5 90 D2937 Pass
Location : Lot # 9 , Elv/Depth :-7 Feet
Comment :
Technician Signature / DateRamchandra Mogulla, November 5, 2020
Reviewer Name / DateKenneth Mosman, December 10, 2021