Skip to content
Menu
Home
About
Daily Field Report
Density Test Report
Concrete Test Report
Login
Home
About
Daily Field Report
Density Test Report
Concrete Test Report
Home
Daily Field Report
Density test report
Date
*
Project Number
*
2023C111(DOA Fiber Infrastructure Improvements )
Name of the Project
*
Project Location
*
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
Isaac Davis (Isaac Davis)
Observations/Finding
Summary
*
<strong>Project Report: DOA Fiber Enhancement Vault #1</strong> <em>Project Overview:</em> <ul> <li><strong>Jobsite:</strong> DOA Fiber Enhancement Vault #1</li> <li><strong>Contractor:</strong> BBH/Athena</li> <li><strong>Concrete Company:</strong> Ernst</li> </ul> <em>Concrete Delivery Details:</em> <ul> <li><strong>Concrete Trucks:</strong> #257 & #253</li> <li><strong>Concrete Volume:</strong> 18.10 cubic yards</li> <li><strong>Actual Poured Volume:</strong> 18.0 cubic yards</li> <li><strong>Concrete Load Type:</strong> 9 Yrd loads</li> <li><strong>Water Addition:</strong> Truck #257 added 25 gallons of water at Contractor's request</li> </ul> <em>Concrete Specifications:</em> <ul> <li><strong>Strength Requirement:</strong> 3000 PSI</li> <li><strong>Test Results:</strong> <ul> <li>Slump (S): 2.75 inches</li> <li>Air Content (A): 4.6% (QC), 4.4% (QA)</li> <li>Temperature (T): 60 degrees</li> <li>Unit Weight (UW): 143 lbs/cubic foot</li> </ul> </li> </ul> <em>Quality Control and Assurance:</em> <ul> <li>The concrete mix meets the specified strength requirement of 3000 PSI.</li> <li>Slump test indicates a workable consistency (S: 2.75 inches).</li> <li>Air content falls within acceptable limits (A: 4.6% QC, 4.4% QA).</li> <li>Temperature as per industry standards (T: 60 degrees).</li> <li>Unit weight is within the specified range (UW: 143 pounds per cubic foot).</li> </ul> <em>Contractor's Request:</em> <ul> <li>Truck #257 accommodated a water addition of 25 gallons as per the contractor's request.</li> </ul> <em>Conclusion:</em> The concrete placement at DOA Fiber Enhancement Vault #1 by BBH/Athena using concrete from Ernst has been successfully executed. The delivered concrete meets the specified strength requirements and exhibits satisfactory properties according to quality control and assurance tests. The additional water added to Truck #257 was in accordance with the contractor's requirements.
Upload Images
Image
Description
1
2
3
4
1
Add Row
Post Status custom
Validate Email
Visual
Text
Insert/edit link
Close
Enter the destination URL
URL
Link Text
Open link in a new tab
Or link to existing content
Search
No search term specified. Showing recent items.
Search or use up and down arrow keys to select an item.
Cancel