Daily Field Report
Density test report
Date
*
Project Number
*
2023C111(DOA Fiber Infrastructure Improvements )
Name of the Project
*
Project Location
*
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
Isaac Davis (Isaac Davis)
Observations/Finding
Summary
*
<strong>Density Report for Jobsite - RTR Fiber (Tower Duct Bank)</strong> <em>Project Overview:</em> The RTR Fiber jobsite, located between Mike 14 and Mike 12, is undergoing construction of a tower duct bank. The contractor for this project is BBH. The construction involves the excavation of a trench to an approximate depth of 4 feet, followed by the placement of a pre-cast duct bank designed for two-way 4-inch pipes. Each pre-cast duct bank segment measures roughly 1 foot in height and 10 feet in length. After placement, backfilling is done with an approximate 3 feet cover on top of the pre-cast duct bank. <em>Density Assessment:</em> The density report focuses on key elements such as trench excavation, pre-cast duct bank placement, backfilling, and preliminary test results. <strong>1. Trench Excavation:</strong> <ul> <li>Depth: The trench was excavated to an approximate depth of 4 feet.</li> <li>Quality: The excavation process aimed to meet the required specifications for the subsequent installation of the duct bank.</li> </ul> <strong>2. Pre-cast Duct Bank Installation:</strong> <ul> <li>Design: The pre-cast duct bank is designed to accommodate two-way 4-inch pipes.</li> <li>Dimensions: Each pre-cast duct bank segment measures approximately 1 foot in height and 10 feet in length.</li> <li>Placement: The duct bank segments were properly positioned within the excavated trench.</li> </ul> <strong>3. Backfilling:</strong> <ul> <li>Depth: Backfilling was performed with an approximate 3 feet cover on top of the pre-cast duct bank.</li> <li>Compaction: The backfilling process aimed to achieve proper compaction to ensure stability and support.</li> </ul> <strong>4. Preliminary Test Results (T1 and T2):</strong> <ul> <li><em>T1:</em> <ul> <li>WD (Wet Density): 108.3</li> <li>DD (Dry Density): 83.8</li> <li>M% (Moisture Content): 29.3%</li> </ul> </li> <li><em>T2:</em> <ul> <li>WD (Wet Density): 106.8</li> <li>DD (Dry Density): 81.8</li> <li>M% (Moisture Content): 30.6%</li> </ul> </li> </ul> <strong>5. Project Progress:</strong> <ul> <li>Approximately 200 feet of the duct bank has been completed.</li> </ul> <em>Observations:</em> <ul> <li>Trench excavation, pre-cast duct bank placement, and backfilling have been executed according to project specifications.</li> <li>Preliminary test results indicate density and moisture content, with further analysis pending the acquisition of the proctor.</li> </ul>
Upload Images
Image
Description
1
2
3
4
5
6
7
8
9
10
1
Add Row
Post Status custom
Validate Email
Visual
Text
Insert/edit link
Close
Enter the destination URL
URL
Link Text
Open link in a new tab
Or link to existing content
Search
No search term specified. Showing recent items.
Search or use up and down arrow keys to select an item.
Cancel