Skip to content
Menu
Home
About
Daily Field Report
Density Test Report
Concrete Test Report
Login
Home
About
Daily Field Report
Density Test Report
Concrete Test Report
Home
Daily Field Report
Density test report
Date
*
Project Number
*
2023C144 (draft)(Carodel Farms @ Union Church Rd)
Name of the Project
*
Project Location
*
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
Vidal Shengan (Vidal Shengan)
Observations/Finding
Summary
*
<div class="flex-1 overflow-hidden"> <div class="react-scroll-to-bottom--css-ecngx-79elbk h-full dark:bg-gray-800"> <div class="react-scroll-to-bottom--css-ecngx-1n7m0yu"> <div class="flex flex-col text-sm dark:bg-gray-800"> <div class="group w-full text-gray-800 dark:text-gray-100 border-b border-black/10 dark:border-gray-900/50 bg-gray-50 dark:bg-[#444654]"> <div class="flex p-4 gap-4 text-base md:gap-6 md:max-w-2xl lg:max-w-[38rem] xl:max-w-3xl md:py-6 lg:px-0 m-auto"> <div class="relative flex w-[calc(100%-50px)] flex-col gap-1 md:gap-3 lg:w-[calc(100%-115px)]"> <div class="flex flex-grow flex-col gap-3"> <div class="min-h-[20px] flex items-start overflow-x-auto whitespace-pre-wrap break-words flex-col gap-4"> <div class="markdown prose w-full break-words dark:prose-invert light"> Our AS Engineering and Consulting (ASEC) representative visited the Carodel Farms site to conduct quality control inspection and testing services. Visual observation techniques were employed to ensure compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were made on-site: <ol> <li>Installation of manhole 50: The contractor installed manhole 50 with 4 inches of #57 stone placed at the bottom before placing the manhole. The quality control representative visually inspected the installation and verified that it met the project requirements.</li> <li>Installation of HDPE Pipe: Between manhole 50 and manhole 37, the contractor installed HDPE (High-Density Polyethylene) pipe. Before placing the pipes, the contractor prepared the bottom with 4 inches of #57 stone and also covered the pipes with 4 inches of stone. The quality control representative visually assessed the installation and confirmed that it was executed according to the project specifications.</li> <li>Backfilling Operations: The contractor placed backfill for Detention Pond 1C and Detention Pond 1B. The quality control representative visually inspected the backfilling operations in accordance with project requirements.</li> <li>Drilling Operations: Driller 1 drilled a total of 60 holes with a drilled area of 2,940 cubic feet. The hole spacing length was 7 feet by 7 feet, and the hole diameter was 4 inches. Driller 2 drilled 18 holes with a drilled area of 882 cubic feet. And performed some rock tests on Lots #62 to 72.</li> </ol> </div> </div> </div> </div> </div> </div> </div> </div> </div> </div>
Upload Images
Image
Description
1
2
3
4
5
6
1
Add Row
Post Status custom
Validate Email
Visual
Text
Insert/edit link
Close
Enter the destination URL
URL
Link Text
Open link in a new tab
Or link to existing content
Search
No search term specified. Showing recent items.
Search or use up and down arrow keys to select an item.
Cancel