2023C111(DOA Fiber Infrastructure Improvements )
Name of the Project
*
Project Location
*
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
Isaac Davis (Isaac Davis)
Observations/Finding
Summary
*
As requested, our ASEC representative was on site to observe site activities this day. The following was observed and peformed: <p class="x_-2026765316p1"><span class="x_-2026765316s1">On-site density testing for DOA Fiber DOA 17A </span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Date: 05/23/23-05/24/23</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Location: DOA Fiber [DOA 17A, north side of north parking Deck]</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Objective:</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">The objective of this report is to provide a summary of the density test conducted at the DOA Fiber DOA 17A site. The density test was carried out by an ASEC technician Isaac Davis to assess the compaction and moisture levels of various lifts within the project area.</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Procedure:</span></p> <ol class="x_-2026765316ol1"> <li class="x_-2026765316li1"><span class="x_-2026765316s1">ASEC technician arrived on site at DOA 17A.</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">BBH contractors completed conduit installation, tying it into the manhole.</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Density test readings were taken for each lift as described below:</span></li> </ol> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Test Results:</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Lift #1:</span></p> <ul class="x_-2026765316ul1"> <li style="list-style-type: none"> <ul class="x_-2026765316ul1"> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Initial Test Reading:</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Wet Density: 127.0 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Dry Density: 116.0 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Moisture Content: 10.3%</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Compaction: 93.6%</span></li> </ul> </li> </ul> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Lift #2:</span></p> <ul class="x_-2026765316ul1"> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Wet Density: 121.1 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Dry Density: 117.1 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Moisture Content: 3.4%</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Compaction: 94.5%</span></li> <li></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Retest Reading </span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Wet Density: 123.1 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Dry Density: 115.7 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Moisture Content: 6.4%</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Compaction: 93.3%</span></li> </ul> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Lift #3:</span></p> <ul class="x_-2026765316ul1"> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Wet Density: 121.4 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Dry Density: 113.5 pcf</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Moisture Content: 7.0%</span></li> <li class="x_-2026765316li1"><span class="x_-2026765316s1">Compaction: 91.6%</span></li> </ul> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Conclusion:</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Upon completion of the density tests, it was observed that the measured values for all lifts were within the specified limits, indicating satisfactory compaction and moisture levels. The project area at DOA 17A met the required specifications based on the test results.</span></p> <p class="x_-2026765316p1"><span class="x_-2026765316s1">Please feel free to reach out if you have any further questions or require additional information.</span></p>
Upload Images
Image
Description
1
2
3
1
Add Row
Post Status custom
Validate Email
Visual
Text
Insert/edit link
Close
Enter the destination URL
URL
Link Text
Open link in a new tab
Or link to existing content
Search
No search term specified. Showing recent items.
Search or use up and down arrow keys to select an item.
Cancel