Density Test Report
Date :04/08/2021
Project No :
Client Company :Toll Bros. Inc.
Arrival Time :04/08/2021 09:00
Onsite Hours :05:00
Name of the Project :Northfields at Polo Fields
Project Location :4805 Pittman Road, Forsyth County, Georgia
Weather :Sunny
Departure Time :04/08/2021 14:00
ASEC Technician Name :Andrew McCullough
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/08/2021 | 1 | 24.0 | 93.5 | P-1 | 97.7 | 22.2 | 95.7 | 95 | D6938 | Pass |
Location : | Rear of lot 4, Elv/Depth :1087 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 2 | 24 | 93.5 | P-1 | 97.7 | 22.2 | 95.7 | 95 | D6938 | Pass |
Location : | Front of lot 4, Elv/Depth :1087 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 3 | 22.1 | 97.1 | P-1 | 97.7 | 22.2 | 99.4 | 95 | D6938 | Pass |
Location : | Rear of lot 3, Elv/Depth :1086 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 4 | 23 | 95.6 | P-1 | 97.7 | 22.2 | 97.9 | 95 | D6938 | Pass |
Location : | Front of lot 3, Elv/Depth :1086 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 5 | 23.0 | 116.0 | P-1 | 97.7 | 22.2 | 96.5 | 95 | D6938 | Pass |
Location : | Rear of lot 2, Elv/Depth :1085 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 6 | 23.0 | 94.4 | P-1 | 97.7 | 22.2 | 96.6 | 95 | D6938 | Pass |
Location : | Front of lot 2, Elv/Depth :1085 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 7 | 25.0 | 93.1 | P-1 | 97.7 | 22.2 | 95.3 | 95 | D6938 | Pass |
Location : | Center of building lot 2, Elv/Depth :1085 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 8 | 24.0 | 94.4 | P-1 | 97.7 | 22.2 | 96.6 | 95 | D6938 | Pass |
Location : | Center of building lot 3, Elv/Depth :1086 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
04/08/2021 | 9 | 24.0 | 95.0 | P-1 | 97.7 | 22.2 | 97.2 | 95 | D6938 | Pass |
Location : | Center of building lot 4, Elv/Depth :1087 | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateAndrew McCullough, April 8, 2021
Reviewer Name / DateRamchandra Mogulla, April 12, 2021