Daily Field Report

Date :10/10/2024
Project No :2024C217
Client Company :Artisan
Arrival Time :10/10/2024 08:35
Onsite Hours :08:15
Name of the Project :Naturewalk - 7 Hills Amenities
Project Location :Dallas
Weather :sunny
Departure Time :10/10/2024 16:45
ASEC Technician Name :Vamsi Polisetty

Observations/Finding

As requested, the site was visited by our AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services.  Visual observation techniques were employed to verify compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were observed on site this day.

  • Upon arrival, the contractor was engaged in excavation using a Komatsu PC 360LC to the North of the project site near the Roadway. Dirt was being transported with two tandem dump truck, while dozing and leveling were performed with a Komatsu D85EX. Compaction work was carried out using a CAT 563 E.
  • Compaction testing was performed using a Troxler nuclear density gauge, along with general probing using a 3/8″ diameter probe rod on the Club house area and on the Pool area.
  • Density test results indicate that compacted materials did meet the project requirement of 95% of the maximum dry density obtained by a Standard Proctor ASTM 698 on the Club house area.
  • Density test results indicate that compacted materials did not meet the project requirement of 95% of the maximum dry density obtained by a Standard Proctor ASTM 698 on the Pool area. Necessary instructions are made to the super intendent for the proper Compaction and visual approval is made from the instructions made from the head office using the proof rolling method.

We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report, please feel free to contact us. We will be more than happy to discuss it with you

Technician Signature / DateVamsi Polisetty, October 10, 2024