- Home
- Density Test Report Report ID: 68659
- Edit Download Report
Density Test Report
Date :08/09/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :08/09/2024
Onsite Hours :
Name of the Project :Sterlington
Project Location :Canton
Weather :sunny
Departure Time :08/09/2024
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/09/2024 | 1 | 2.5 | 141.3 | P-03 | 146.7 | 4.3 | 96.3 | 100 | D6938 | Fail |
Location : | Cul-de-sac main roadway, Elv/Depth :finished grade | |||||||||
Comment : | requires addition of moisture and recompaction and retesting | Gauge Serial No. :30942 | ||||||||
08/09/2024 | 2 | 2.8 | 134.7 | P-03 | 146.7 | 4.3 | 91.8 | 100 | D6938 | Fail |
Location : | 200 feet from cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | requires addition of moisture and recompaction and retesting | Gauge Serial No. :30942 | ||||||||
08/09/2024 | 3 | 1.6 | 144.5 | P-03 | 146.7 | 4.3 | 98.5 | 100 | D6938 | Fail |
Location : | 500 feet from cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | requires addition of moisture and recompaction and retesting | Gauge Serial No. :30942 | ||||||||
08/09/2024 | Retest of Test #1 | 3.7 | 148.9 | P-03 | 146.7 | 4.3 | 101.5 | 100 | D6938 | Pass |
Location : | Cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | Retest of Test #2 | 3.6 | 152.6 | P-03 | 146.7 | 4.3 | 100.4 | 100 | D6938 | Pass |
Location : | 20 feet from Cul-de-sacs, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | Retest of Test #3 | 3.8 | 153.0 | P-03 | 146.7 | 4.3 | 100.5 | 100 | D6938 | Pass |
Location : | 50 feet from Cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 4 | 4.0 | 147.0 | P-03 | 146.7 | 4.3 | 100.2 | 100 | D6938 | Pass |
Location : | 100 feet from cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 5 | 4.2 | 153.9 | P-03 | 146.7 | 4.3 | 100.7 | 100 | D6938 | Pass |
Location : | 150 feet from cul-de-sac, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 6 | 5.2 | 147.1 | P-03 | 146.7 | 4.3 | 100.3 | 100 | D6938 | Pass |
Location : | Main roadway in front of parking spaces, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 7 | 3.5 | 146.8 | P-03 | 146.7 | 4.3 | 100.1 | 100 | D6938 | Pass |
Location : | Main roadway 50 feet from parking spaces, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 8 | 2.4 | 148.4 | P-03 | 146.7 | 4.3 | 101.2 | 100 | D6938 | Pass |
Location : | 100 feet from parking spaces, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 9 | 2.6 | 149.1 | P-03 | 146.7 | 4.3 | 101.6 | 100 | D6938 | Pass |
Location : | 250 feet from parking spaces, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 | |||||||||
08/09/2024 | 10 | 2.7 | 147.9 | P-03 | 146.7 | 4.3 | 100.8 | 100 | D6938 | Pass |
Location : | Decel lane, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :30942 |
Technician Signature / DateRussell Hendrix, August 9, 2024
Reviewer Name / DateKenneth Mosman, August 12, 2024