Density Test Report

Date :07/08/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :07/08/2024 8:30
Onsite Hours :08:30
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :Sunny
Departure Time :07/08/2024 17:00
ASEC Technician Name :Fawad Shagiwal

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/08/2024 1 14.7 113.0 P-01 108.9 17.9 103.8 95 D6938 Pass
Location : Lot #86, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :38069
07/08/2024 2 17.8 103.7 P-02 107.4 20.2 96.6 95 D6938 Pass
Location : Lot #83, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :38069
07/08/2024 3 18.2 110.8 P-02 107.4 20.2 103.2 95 D6938 Pass
Location : Lot #72, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :38069
07/08/2024 4 15.8 104.5 P-01 108.9 17.9 96.0 95 D6938 Pass
Location : Lot #70, Elv/Depth :3 feet below finished grade.
Comment : Gauge Serial No. :38069
Technician Signature / DateFawad Shagiwal, July 8, 2024
Reviewer Name / DateKenneth Mosman, July 27, 2024