Skip to content

Density Test Report

Date :06/25/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :06/25/2024 9:00
Onsite Hours :08:00
Name of the Project :Sterlington
Project Location :Canton
Weather :sunny
Departure Time :06/25/2024 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/25/2024 1 15.4 96.6 P-02 105.9 18.8 91.2 95 D6938 Fail
Location : Lot #19, Elv/Depth :0.5 feet below finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/25/2024 2 14.5 96.2 P-02 105.9 18.8 90.8 95 D6938 Fail
Location : Lot #20, Elv/Depth :1 foot below finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/25/2024 3 13.7 97.5 P-02 105.9 18.8 92.1 95 D6938 Fail
Location : Lot #19, Elv/Depth :finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
06/25/2024 4 15.1 97.3 P-02 105.9 18.8 91.9 95 D6938 Fail
Location : Lot #20, Elv/Depth :finished grade
Comment : moisture content was below specified moisture limit. Gauge Serial No. :38069
Technician Signature / DateAminullah Azimi, June 25, 2024
Reviewer Name / DateKenneth Mosman, July 25, 2024