Density Test Report

Date :05/29/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :05/29/2024
Onsite Hours :
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :sunny
Departure Time :05/29/2024
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/28/2024 1 16.2 125.0 P-01 108.9 17.9 98.8 95 D6938 Pass
Location : Section 1 south side, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :30942
05/28/2024 2 17.8 105.7 P-01 108.9 17.9 97.1 95 D6938 Pass
Location : Section 1 west side, Elv/Depth :Finished grade
Comment : Also, this area was proof-rolled Gauge Serial No. :30942
Technician Signature / DateRussell Hendrix, May 29, 2024
Reviewer Name / DateKenneth Mosman, July 15, 2024