Skip to content

Density Test Report

Date :05/22/2024
Project No :2024C112
Client Company :SR Homes
Arrival Time :05/22/2024 10:00
Onsite Hours :07:00
Name of the Project :Sterlington
Project Location :Canton
Weather :sunny
Departure Time :05/22/2024 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/22/2024 1 15.5 96.2 P-02 105.9 18.8 90.8 95 D6938 Fail
Location : Lot #12, Elv/Depth :4 feet below finished grade
Comment : Recompaction required. In-situ moisture content more than 2 percent above optimum moisture content Gauge Serial No. :38069
05/22/2024 2 15.8 96.8 P-02 105.9 18.8 91.4 95 D6938 Fail
Location : Lot #12, Elv/Depth :5 feet below finished grade
Comment : Recompaction required. In-situ moisture content more than 2 percent above optimum moisture content Gauge Serial No. :38069
05/22/2024 3 15.7 97.2 P-02 105.9 18.8 91.8 95 D6938 Fail
Location : Lot #12, Elv/Depth :3 feet below finished grade
Comment : Recompaction required. In-situ moisture content more than 2 percent above optimum moisture content Gauge Serial No. :38069
Technician Signature / DateAminullah Azimi, May 22, 2024
Reviewer Name / DateKenneth Mosman, July 12, 2024