- Home
- Density Test Report Report ID: 66517
- Edit Download Report
Density Test Report
Date :05/13/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :05/13/2024 7:30
Onsite Hours :08:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :05/13/2024 15:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/13/2024 | 1 | 3.9 | 134.6 | 2 | 141.4 | 5.7 | 95.2 | 95 | D6938 | Pass |
Location : | In-line valve at STA 7016+27, Elv/Depth :1.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
05/13/2024 | 2 | 4.9 | 134.3 | 2 | 141.4 | 5.7 | 95.0 | 95 | D6938 | Fail |
Location : | In-line valve at STA 7016+27, Elv/Depth :6 inches below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateAminullah Azimi, May 13, 2024
Reviewer Name / DateKenneth Mosman, July 10, 2024