Skip to content

Density Test Report

Date :05/10/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :05/10/2024 8:00
Onsite Hours :9:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :05/10/2024 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/10/2024 1 6.2 134.7 2 141.4 5.7 95.3 95 D6938 Pass
Location : bend 30, STA 7021+32.82, Elv/Depth :finished grade
Comment : Gauge Serial No. :38069
05/10/2024 2 9.5 118.5 9 120.8 11.3 98.1 95 D6938 Pass
Location : in line valve, STA 7016+27, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :38069
05/10/2024 3 5.3 135.2 2 141.4 5.7 95.6 95 D6938 Pass
Location : in line valve, STA 7016+27, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :38069
Technician Signature / DateAminullah Azimi, May 10, 2024
Reviewer Name / DateKenneth Mosman, July 10, 2024