- Home
- Density Test Report Report ID: 66430
- Edit Download Report
Density Test Report
Date :05/06/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :05/06/2024 11:30
Onsite Hours :06:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :sunny
Departure Time :05/06/2024 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/06/2024 | 1 | 5.5 | 128.2 | 2 | 141.4 | 5.7 | 90.7 | 90 | D6938 | Pass |
Location : | Bend 30, STA 7021+32.82, Elv/Depth :4 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
05/06/2024 | 2 | 6.5 | 135.6 | 2 | 141.4 | 5.7 | 90.0 | 90 | D6938 | Fail |
Location : | Bend 30, STA 7021+32.82, Elv/Depth :3.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
05/06/2024 | 3 | 10 | 116.8 | 4 | 122.7 | 10.6 | 95.2 | 90 | D6938 | Pass |
Location : | Bend 30, STA 7021+32.82, Elv/Depth :3 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateAminullah Azimi, May 6, 2024
Reviewer Name / DateKenneth Mosman, May 24, 2024