- Home
- Density Test Report Report ID: 65959
- Edit Download Report
Density Test Report
Date :04/11/2024
Project No :2022C106
Client Company :CWM
Arrival Time :04/11/2024 8:00
Onsite Hours :08:00
Name of the Project :Taxiway 2022 Pavement Replacement
Project Location :HJAIA
Weather :sunny
Departure Time :04/11/2024 16:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/11/2024 | 1 | 8 | 121.4 | Infinity | D6938 | Pass | ||||
Location : | storm water line, 9 feet to North from MH A-2, Elv/Depth :3 feet below finish grade | |||||||||
Comment : | need add M10 proctor for result | Gauge Serial No. :85759 | ||||||||
04/11/2024 | 2 | 8.7 | 119.0 | Infinity | D6938 | Pass | ||||
Location : | storm water line, 65 feet to south from A-4,, Elv/Depth :2 feet below finish grade | |||||||||
Comment : | Need to add M10 proctor in the system for result. | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 11, 2024
Reviewer Name / DateKenneth Mosman, April 26, 2024