- Home
- Density Test Report Report ID: 65770
- This project is inactive from admin.Download Report
Density Test Report
Date :04/02/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :04/01/2024 8:00
Onsite Hours :04:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :04/01/2024 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/01/2024 | 1 | 15.3 | 100.9 | 24469 | 103.9 | 18.7 | 97.1 | 95 | D6938 | Pass |
Location : | Lot #35, Elv/Depth :finished grade | |||||||||
Comment : | Moisture content higher than 3 percent over optimum moisture | Gauge Serial No. :85759 | ||||||||
04/01/2024 | 2 | 15.8 | 105.9 | 24468 | 111.3 | 17.5 | 95.1 | 95 | D6938 | Pass |
Location : | Lot #51 basement., Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
04/02/2024 | 3 | 15.3 | 100.9 | 24469 | 103.9 | 18.7 | 97.1 | 95 | D6938 | Pass |
Location : | Lot #51, Elv/Depth :3.5 feet below finished grade | |||||||||
Comment : | Moisture content higher than 3 percent over optimum moisture | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 2, 2024
Reviewer Name / DateKenneth Mosman, April 25, 2024